Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(11): 2316-2329, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37655997

RESUMO

The right bundle branch (RBB), due to its endocardial course, is susceptible to traumatic block caused by "bumping" during right-heart catheterization. In the era of cardiac electrophysiology, catheter-induced RBB block (CI-RBBB) has become a common phenomenon observed during electrophysiological studies and catheter ablation procedures. While typically transient, it may persist for the entire procedure time. Compared to pre-existing RBBB, the transient nature of CI-RBBB allows for comparative analysis relative to the baseline rhythm. Furthermore, unlike functional RBBB, it occurs at similar heart rates, making the comparison of conduction intervals more reliable. While CI-RBBB can provide valuable diagnostic information in various conditions, it is often overlooked by cardiac electrophysiologists. Though it is usually a benign and self-limiting conduction defect, it may occasionally lead to diagnostic difficulties, pitfalls, or undesired consequences. Avoidance of CI-RBBB is advised in the presence of baseline complete left bundle branch block and when approaching arrhythmic substrates linked to the right His-Purkinje-System, such as fasciculo-ventricular pathways, bundle branch reentry, and right-Purkinje focal ventricular arrhythmias. This article aims to provide a comprehensive practical review of the electrophysiological phenomena related to CI-RBBB and its impact on the intrinsic conduction system and various arrhythmic substrates.


Assuntos
Bloqueio de Ramo , Sistema de Condução Cardíaco , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração , Cateterismo Cardíaco/efeitos adversos , Catéteres , Eletrocardiografia
2.
J Interv Card Electrophysiol ; 66(8): 1877-1888, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36795268

RESUMO

BACKGROUND: To predict the outflow tract ventricular arrhythmias (OTVA) site of origin (SOO) before the ablation procedure has important practical implications. The present study sought to prospectively evaluate the accuracy of a clinical and electrocardiographic hybrid algorithm (HA) for the prediction of OTVAs-SOO, and at the same time to develop and to prospectively validate a new score with improved discriminatory capacity. METHODS: In this multicenter study, we prospectively enrolled consecutive patients referred for OTVA ablation (N = 202), and we divided them in a derivation sample and a validation cohort. Surface ECGs during OTVA were analyzed to compare previous published ECG-only criteria and to develop a new score. RESULTS: In the derivation sample (N = 105), the correct prediction rate of HA and ECG-only criteria ranged from 74 to 89%. R-wave amplitude in V3 was the best ECG parameter for discriminating LVOT origin in V3 precordial transition (V3PT) patients, and was incorporated to the novel weighted hybrid score (WHS). WHS correctly classified 99 (94.2%) patients, presenting 90% sensitivity and 96% specificity (AUC 0.97) in the entire population; WHS mantained a 87% sensitivity and 91% specificity (AUC 0.95) in patients with V3PT subgroup. The high discriminatory capacity was confirmed in the validation sample (N = 97): the WHS exhibited an AUC (0.93), and a WHS ≥ 2 allowed a correct prediction of LVOT origin in 87 (90.0%) cases, yielding a sensitivity of 87% and specificity of 90%; moreover, the V3PT subgroup showed an AUC of 0.92, and a punctuation ≥ 2 predicted an LVOT origin with a sensitivity of 94% and specificity of 78%. CONCLUSIONS: The novel hybrid score has proved to accurately anticipate the OTVA's origin, even in those with a V3 precordial transition. A Weighted hybrid score. B Typical examples of the use of the weighted hybrid score. C ROC analysis of WHS and previous ECG criteria for prediction of LVOT origin in the derivation cohort. D ROC analysis of WHS and previous ECG criteria for prediction of LVOT origin in the V3 precordial transition OTVA subgroup.

3.
J Cardiovasc Electrophysiol ; 34(3): 598-606, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36640425

RESUMO

INTRODUCTION: Despite numerous ECG algorithms being developed to localize the site of manifest accessory pathways (AP), they often require stepwise multiple-lead analysis with variable accuracy, limitations, and reproducibility. The study aimed to develop a single-lead ECG algorithm incorporating the P-Delta interval (PDI) as an adjunct criterion to discriminate between right and left manifest AP. METHODS: Consecutive WPW patients undergoing electrophysiological study (EPS) were retrospectively recruited and split into a derivation and validation group (1:1 ratio). Sinus rhythm ECG analysis in lead V1 was performed by three independent investigators blinded to the EPS results. Conventional ECG parameters and PDI were assessed through the global cohort. RESULTS: A total of 140 WPW patients were included (70 for each group). A score-based, single-lead ECG algorithm was developed through derivation analysis incorporating the PDI, R/S ratio, and QRS onset polarity in lead V1. The validation group analysis confirmed the proposed algorithm's high accuracy (95%), which was superior to the previous ones in predicting the AP side (p < 0.05). A score of ≤+1 was 96.5% accurate in predicting right AP while a score of ≥+2 was 92.5% accurate in predicting left AP. The new algorithm maintained optimal performance in specific subgroups of the global cohort showing an accuracy rate of 90%, 92%, and 96% in minimal pre-excitation, posteroseptal AP, and pediatric patients, respectively. CONCLUSIONS: A novel single-lead ECG algorithm incorporating the PDI interval with previous conventional criteria showed high accuracy in differentiating right from left manifest AP comprising pediatric and minimal pre-excitation subgroups in the current study.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Criança , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Algoritmos , Síndrome de Wolff-Parkinson-White/cirurgia
4.
Int J Cardiol ; 375: 23-28, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36587656

RESUMO

BACKGROUND: This study aimed to collect and analyze the literature data regarding Chiari network (CN) and other right atrium (RA) remnants comprising the Eustachian and Thebesian valves (EV, ThV) as a potential entrapment site during different percutaneous cardiac procedures (PCP). METHODS AND RESULTS: A systematic search was conducted using Pubmed and Embase databases following the PRISMA guidelines to obtain available data concerning PCP associated with entrapment of inserted materials within CN-EV-ThV. The final analysis included 41 patients who underwent PCP with reported material entrapment within these RA remnants. The PCP was atrial septal defect (ASD)/patent foramen ovale (PFO) closure, catheter ablation, and pacemaker/defibrillator implantation in 44%, 22%, and 17% of patients, respectively. The entrapped materials were ASD/PFO devices, multipolar electrophysiology catheters, passive-fixation pacing leads, and J-guidewires in about 30%, 20%, 15%, and 10% of patients, respectively. Intraprocedural transthoracic, transoesophageal and intracardiac echocardiography showed sensitivity to reveal these structures of 20%, ∼95%, and 100%, respectively. A percutaneous approach successfully managed 70% of patients, while cardiovascular surgery was required in 20% and three patients died (7.3%). CONCLUSIONS: CN and other RA remnants may cause entrapment of various devices or catheters during PCP requiring right heart access. The percutaneous approach, guided by intraprocedural imaging, appears safe and effective in managing most patients. Prevention includes recognizing these anatomical structures at baseline cardiac imaging and intraprocedural precautions. Further studies are needed to analyze the actual incidence of this condition, its clinical impact and appropriate management.


Assuntos
Cardiologistas , Forame Oval Patente , Comunicação Interatrial , Humanos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/epidemiologia , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/epidemiologia , Forame Oval Patente/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Próteses e Implantes , Resultado do Tratamento
5.
Minerva Cardiol Angiol ; 71(6): 622-630, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36305779

RESUMO

INTRODUCTION: To evaluate the clinical outcomes of oral mexiletine (oMXT) to treat ventricular tachyarrhythmias (VTAs) in the era of implantable cardioverter-defibrillator (ICD) technology. EVIDENCE ACQUISITION: A systematic search was conducted using PubMed, Embase and Cochrane databases following the PRISMA guidelines to collect literature data reporting oMXT efficacy and safety outcomes in treating VTAs in ICD recipients. EVIDENCE SYNTHESIS: Final analysis included four studies accounting for a total of 91 patients with recurrent VTAs treated with oMXT. Amiodarone therapy was initially attempted in most patients (91.2%), while catheter ablation was performed in one-third of patients. VTA recurrences were observed in 55/91 patients (60.4%) during oMXT treatment compared to 91/91 (100%) before treatment (P<0.001). Appropriate therapies occurred in 55/88 ICD patients (62.5%) during oMXT treatment compared to 80/88 (90.9%) before treatment (P<0.001). After oMXT introduction, there was a significant reduction of the individual burden of VTA episodes and appropriate ICD therapies per patient, showing Hedges'g values of -1.103 (P=0.002) and -1.474 (P=0.008), respectively. Safety analysis showed a sample-weighted overall side-effect rate of 30%, while 21% of patients required drug reduction or discontinuation. Aggregated meta-regression analysis of the included studies and remote literature revealed a linear correlation between oMXT dosage and the overall side effects rate (r2 = 0.48; P=0.014). CONCLUSIONS: Oral mexiletine provides an adjunctive treatment to manage VTAs and reduces appropriate therapies in ICD patients with moderate efficacy and acceptable safety profiles. These observations await confirmation through randomised clinical trials.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Mexiletina/uso terapêutico , Desfibriladores Implantáveis/efeitos adversos , Antiarrítmicos/efeitos adversos , Resultado do Tratamento , Taquicardia Ventricular/tratamento farmacológico
6.
Europace ; 24(10): 1608-1616, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35639806

RESUMO

AIMS: Air entrapment (AE) has been reported as a potential cause of early inappropriate shocks (ISs) following subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, but a cause-effect relationship is not always evident. This systematic review aims to analyse this phenomenon concerning implantation techniques, electrogram (EGM) features, radiologic findings, and patient management. METHODS AND RESULTS: A systematic search was conducted using PubMed, Embase, and Google Scholar databases following the PRISMA guidelines to obtain all available literature data since 2010 on S-ICD malfunctions possibly due to AE. The final analysis included 54 patients with AE as a potential cause of S-ICD malfunction. Overall, the aggregate incidence of this condition was 1.2%. Of ICD malfunctions possibly due to AE, 93% were ISs, and 95% were recorded within the first week following implantation. Radiologic diagnosis of AE was confirmed in 28% of the entire study cohort and in 68% of patients in whom this diagnostic examination was reported. At the time of device malfunction, EGMs showed artefacts, baseline drift, and QRS voltage reduction in 95, 76, and 67% of episodes, respectively. Management included ICD reprogramming or testing, no action (observation), and invasive implant revision in 57, 33, and 10% of patients, respectively. No recurrences occurred during follow-up, irrespective of management performed. CONCLUSIONS: Device malfunction possibly due to AE may occur in ∼1% of S-ICD recipients. Diagnosis is strongly suggested by early occurrence, characteristic EGM features, and radiologic findings. Non-invasive management, principally device reprogramming, appears to be effective in most patients.


Assuntos
Desfibriladores Implantáveis , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Humanos , Incidência , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 31(8): 2093-2098, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32437006

RESUMO

INTRODUCTION: The prognostic impact of nonsustained ventricular tachycardia (NSVT) morphology has never been explored in hypertrophic cardiomyopathy (HCM). In a single-center cohort of consecutive HCM patients implanted with an implanted cardioverter-defibrillator (ICD), we assessed NSVT morphology patterns and their prognostic implications. METHODS: A cohort of consecutive HCM patients implanted with an ICD was followed from ICD implantation to last follow-up visit. Patients were assessed for NSVT as stored events in ICD memory. Ventricular tachycardias (VTs) were classified as monomorphic (MM) or polymorphic according to intracardiac electrogram morphology. RESULTS: One hundred nine consecutive HCM patients (68 males; mean age: 45 ± 17 years) composed the study population. During follow-up (71 ± 48 months), 7 polymorphic NSVT in 4 patients and 370 MM NSVT in 42 patients were retrieved from ICD memory. Among patients with only MM NSVT, 19 (45%) had one morphology, 17 (41%) had two morphologies, 3 (7%) had three morphologies, and 3 (7%) had four morphologies. Patients with polymorphic NSVT had the highest risk of ICD interventions (HR, 5.04; 95% CI, 1.26-20.19; P = .02). A stepwise increase of the risk of ICD interventions in patients with two, three, and four NSVT morphologies was observed. Out of 16 patients with both NSVT and ICD-treated VTs, 13 (81%) had at least one ICD-treated VT with the same morphology of a previous long-lasting NSVT. CONCLUSIONS: In high-risk HCM patients, the occurrence of polymorphic NSVT and of NSVT with multiple morphologies carries a high risk for ICD interventions. Sustained VTs tend to recur with the same morphology of previous long-lasting NSVTs.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Taquicardia Ventricular , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/terapia , Cardioversão Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia
11.
JACC Clin Electrophysiol ; 5(11): 1233-1252, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31753428

RESUMO

More than 2 decades ago, para-Hisian pacing was introduced to assess the pattern of retrograde conduction during electrophysiological studies. Although there is no ideal maneuver for every patient and condition, para-Hisian pacing is a valuable and handy strategy to differentiate between retrograde conduction over the atrioventricular node and the accessory pathways. The dynamic behavior of para-Hisian pacing, in a region with unique anatomical features, can produce various activation patterns and intriguing electrophysiological phenomena. Although the demonstration of a retrograde nodal activation pattern during para-Hisian pacing does not rule out the presence of an accessory pathway, evidence of retrograde conduction over an accessory pathway does not prove its active role in the culprit tachycardia. Multipolar His bundle recordings, detailed atrial mapping, and recognition of the truly captured structures and the impact of temporal changes of autonomic tone or pacing rates, are essential keys for accurate interpretation of this maneuver that may ultimately guide judicious catheter ablation of the arrhythmic substrate. This review aims to summarize the practical usefulness and potential pitfalls of the para-Hisian pacing maneuver, focusing on the interpretation of electrocardiograms and intracardiac recordings.


Assuntos
Feixe Acessório Atrioventricular/fisiopatologia , Nó Atrioventricular/fisiopatologia , Fascículo Atrioventricular/fisiopatologia , Doença do Sistema de Condução Cardíaco/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Doença do Sistema de Condução Cardíaco/cirurgia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter , Humanos
12.
J Arrhythm ; 35(5): 766-769, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31624519

RESUMO

This case concerns a 24-year-old female who developed malignant ventricular tachyarrhythmia a few weeks after pacemaker implantation for complete heart block. Apparently, right ventricular pacing caused significant repolarization abnormalities in both native and paced rhythms with marked QT prolongation and substantial electrical instability. This case highlights other intriguing phenomena in the puzzle of cardiac repolarization and how pacing therapy may alter this complex process providing arrhythmic substrate in vulnerable subjects. Though such arrhythmic events are clinically rare, vulnerable patients or with suspected myocardial disease that may cause QT prolongation should be carefully followed in the course of pacing therapy.

13.
Pharmacol Res Perspect ; 3(3): e00135, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26171219

RESUMO

Recent findings indicate that fingolimod, the first oral drug approved for the treatment of multiple sclerosis (MS), acts as a direct inhibitor of histone deacetylases (HDACs) and enhances the production of brain-derived neurotrophic factor (BDNF) in the CNS. Both mechanisms are relevant to the pathophysiology and treatment of major depression. We examined the antidepressant activity of fingolimod in mice subjected to chronic unpredictable stress (CUS), a model of reactive depression endowed with face and pharmacological validity. Chronic treatment with fingolimod (3 mg kg(-1), i.p., once a day for 4 weeks) reduced the immobility time in the forced swim test (FST) in a large proportion of CUS mice. This treatment also caused anxiogenic-like effects in the social interaction test without affecting anxiety-like behavior in the elevated plus maze or spatial learning in the water maze. CUS mice showed reduced BDNF levels and enhanced HDAC2 levels in the hippocampus. These changes were reversed by fingolimod exclusively in mice that showed a behavioral response to the drug in the FST. Fingolimod treatment also enhanced H3 histone K14-acetylation and adult neurogenesis in the hippocampus of CUS mice. Fingolimod did not affect most of the parameters we have tested in unstressed control mice. The antidepressant-like activity of fingolimod was confirmed in mice chronically treated with corticosterone. These findings show for the first time that fingolimod exerts antidepressant-like effect acting in a "disease-dependent" manner, and raise the interesting possibility that the drug could relieve depressive symptoms in MS patients independently of its disease-modifying effect on MS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...